MEX vapor recovery pumps for petrol stations

Rely on safe, economical and sustainable vapor recovery - with a MEX vapor recovery pump from Dürr Technik

For decades, our high-quality vapor recovery pumps have been ensuring safe and economical use at petrol stations worldwide. Whether belt or direct drive, classic proportional valve or modern electronic speed control - we will be pleased to advise you on the various models.

The new product series "MEX Vapor Control" is based on a direct drive and has an electronic speed control. The electronic speed control ensures that petrol vapor’s are optimally extracted and at the same time reduces mechanical wear and tear on the engine and other mechanical components, as these only deliver maximum performance when required. This ensures better energy efficiency and a longer service life. Due to the electronic speed control the proportional valve is no longer required.

This technological innovation provides you with a comprehensive vapor recovery solution for use in the petrol pump. At the same time, you are relying on a very durable vapor recovery pump, which offers a great deal of potential for the "Smart Solution" of tomorrow.

Your advantages at a glance

Economical & durable
  • Economical due to high-quality engineering made in Germany
  • Long service life of fuel-resistant bearings and components
  • Constant flow rate over the entire service life due to fuel-resistant bearing grease seal and self-adjusting piston seal
Safe & robust
  • Explosion protection according to ATEX, certified according to ATEX (2014/34/EU), TÜV, QS, PTB and CN-EX
  • Integrated flame arresters on the inlet and outlet side for maximum safety:
    - E85 suitable with IIA flame arresters
    - E100 suitable with IIB1 flame arrester
  • Also suitable as flame arrester in vapor recovery systems
  • Insensitive to condensate and liquid due to a patented pre chamber with integrated drainage system
Versatile & variable
  • Versatile Drive:
    - Belt- or or clutch drive (MEX 0831-11/600)
    - Direct drive (MEX 0544 and MEX Vapor Control)
  • Also suitable for retrofitting
  • Variable mounting positions possible
  • Wide temperature operating range - 40 °C to + 60 °C
Universal & service-friendly
  • Best suited for worldwide operation due to adapted motor speed for 50 Hz and 60 Hz
  • Universally compatible pump heads fit all motor variants
  • Quick and easy disassembly of the pump head from the motor due to special coupling
  • Independent of direction of rotation

 

 

MEX Vapor Control

The all in one solution for your petrol pump.

The vapor recovery pump MEX Vapor Control consists of a particularly compact MEX direct drive 1-cylinder and a frequency converter, which controls the speed of the motor during vapor recovery.

For the installation and calibration of the vapor recovery system the software "DürrTronic MEX-Soft" is available to customers free of charge.

Special advantages of the vapor recovery pump MEX Vapor Control:

  • Reduced operating costs by using an energy efficient IE3 motor with premium efficiency
  • Longer service life and less maintenance thanks to reduced wear of mechanical components through soft starting with low starting currents
  • Precise speed control through frequency converter instead of proportional valve
  • Effective use of electrical energy through high power factor
  • Quiet operation due to the optimal control of the vapour recovery pump for the specific operation

Technical data MEX Vapor Control

      Electrical data    
Flow volume

End pressure

Relay

Rated current

Nominal voltage

Frequency

Frequency converter

Dimensions
  V (l/min) (mbar) (V) (A) (V) (Hz) (V) L x Wx H (mm)
0544100200 with VFD
0545100001
42 at 1800 rpm ~150 without 0,65 230 3~ 50 230 1~ 232 x 160 x 209

Remarks:
V = Volume flow at back pressure pe = 150 mbar and a suction pressure pabs = 900 mbar
Medium to be pumped: Air
Sound level < 70 dB(A)
pabs = absolute pressure

Software download for MEX Vapor Control

The PC software "DürrTronic Mex-Soft" is available to customers free of charge for the installation and calibration of the vapour recovery system "MEX Vapour Control".

Please fill out the form. We will send you the desired software immediately.

The fields marked with a * are mandatory fields.

Please add 8 and 4.

For more information about privacy, please also see the privacy policy of this website.
Your data will not be passed on to third parties.

MEX Direct Drive 1-Cylinder 0544

For use in dispensers with only one dispensing side.

  • ATEX and TÜV certificated
  • Oil- and maintenance free
  • Resistant to condensate and liquid
  • Rotation independent of pump orientation
  • Noise level < 70 dB(A)
  • Protection class IP 10

Technical Data MEX Direct Drive 1-Cylinder 0544

      Electrical data  
Flow volume

End pressure

Relay

Rated Current

Nominal voltage

Frequency Dimensions
  V (l/min) (mbar) (V) (A) (V) (Hz) L x W x H (mm)
 3~Motor 50 Hz
             
0544 1000K 53 ˜ 150 24 DC 0,75 380-415 50 312 x 174 x 201
0544 1100K 53 ˜ 150 without 0,75 380-415 50 312 x 174 x 201
0544 1700K 53 ˜ 150 220-240 AC 0,75 380-415 50 312 x 174 x 201
 1~Motor 50 Hz
             
0544 1200K 53 ˜ 150 24 DC 2,30 220-230 50 367 x 174 x 201
0544 1250K 53 ˜ 150 220-240 AC 2,30 220-230 50 367 x 174 x 201
0544 1300K 53 ˜ 150 without 2,30 220-230 50 367 x 174 x 201
 1~Motor 60 Hz
             
0544 1400K 44 ˜ 150 24 DC 1,80 110-127 60 367 x 174 x 201
0544 1800K 38 ˜ 150 without 1,15 220 60 367 x 174 x 201

Remarks:
V = volume flow at counter pressure pe = 150 mbar and a suction pressure pabs = 900 mbar
Pumping medium: air
Noise level < 70 dB(A)
pabs = absolute pressure

 

MEX Direct Drive 2-Cylinder 0544

For use in dispensers with two dispensing sides.

  • ATEX and TÜV certificated
  • Oil- and maintenance free
  • Resistant to condensate and liquid
  • Rotation independent of pump orientation
  • Noise level < 70 dB(A)
  • Protection class IP 10

Technical Data MEX Direct Drive 2-Cylinder 0544

      Electrical data  

Flow volume

End pressure

Relay

Rated current

Nominal voltage

Frequency Dimensions
  V (l/min) (mbar) (V) (A) (V) (Hz) L x W x H (mm)
 3~Motor 50 Hz
             
0544 2000K 53 ˜ 150 24 DC 1,0 380-415 50 434 x 174 x 201
0544 2100K 53 ˜ 150 without 1,0 380-415 50 434 x 174 x 201
0544 2700K 53 ˜ 150 220-240 AC 1,0 380-415 50 434 x 174 x 201
 1~Motor 50 Hz
             
0544 2200K 53 ˜ 150 24 DC 3,0 220-230 50 489 x 174 x 201
0544 2250K 53 ˜ 150 230 AC 3,0 220-230 50 489 x 174 x 201
0544 2300K 53 ˜ 150 without 3,0 220-230 50 489 x 174 x 201
 1~Motor 60 Hz
             
0544 2400K 44 ˜ 150 24 DC 2,9 110-127 60 489 x 174 x 201
0544 2800K 38 ˜ 150 without 1,7 220 60

489 x 174 x 201

 3~Motor 60 Hz
44 ˜ 150 24 DC 1,2/0,7 230/400 60 434 x 174 x 201

Remarks:
V = volume flow at counter pressure pe = 150 mbar and a suction pressure pabs = 900 mbar
Pumping medium: air
Noise level < 70 dB(A)
pabs = absolute pressure

MEX Belt Drive 0831

  • ATEX and TÜV certificated
  • Oil- and maintenance free
  • Resistant to condensate and liquid
  • Rotation independent of pump orientation
  • Noise level < 70 dB(A)

Technical data MEX Belt Drive 0831

Flow volume End pressure Recommended motor power Max. permissible speed of rotation Dimensions
  V (l/min) (mbar) (W) (1/min) L x W x H (mm)
0831-11/600 44 ˜ 150 150 (200) 2300 117 x 88 x 188

Accessory: belt pulley (94 mm effective diameter), replacement pumps and motors on request.

Remarks:
V = volume flow at counter pressure pe = 150 mbar and a suction pressure pabs = 900 mbar
Pumping medium: air
Noise level < 70 dB(A)
pabs = absolute pressure